IG MARITIME 的国际模拟测试面向所有海员免费开放。注册一次即可保存进度,无限次备考!
CD7032. TOTS 1B-Fixed and Portable Gas Detections Systems
搜索本栏目请选择题集,开始学习或模拟考试。
题集简介
Seagull CBT 栏目提供自学题目。请选择一组题目,开始学习或模拟考试。
「Seagull CBT — CD7032. TOTS 1B-Fixed and Portable Gas Detections Systems」共有 1 个题集、36 道题。
学习
学习模式不限时。答题后可查看结果和正确选项,也可返回题目复习。
模拟考试
模拟考试最长 60 分钟,最多 50 道题。完成后可查看正确答案和成绩。
示例题目与答案
以下为题集中的示例。选择学习练习答题,或选择模拟考试检验知识。
What instrument should you use to test for very low levels of oxygen before loading a sensitive cargo?
单选
- Chemical indicator tubes.✓ 正确答案
- A paramagnetic oxygen analyser.
- An Explosimeter.
- An infrared gas detector.
How will leaks in the sampling line affect the operation of portable gas detection equipment?
单选
- It will cause lower readings due to dilution of the sample.✓ 正确答案
- It will cause higher readings due to increased flow rate.
- It will cause failure due to low suction pressure.
- It will cause failure due to high flow rate.
If an Explosimeter is calibrated using span gas containing 1% butane in air, what reading may be expected?
单选
- Approximately 50% Lower Flammable Limit.✓ 正确答案
- Approximately 10% Lower Flammable Limit.
- Approximately 100% Lower Flammable Limit.
- Approximately 1% Lower Flammable Limit.
What is the composition of the span gas generally used for calibration of an Explosimeter?
单选
- Approximately 1% butane in air.✓ 正确答案
- Pure carbon dioxide.
- A proprietary mixture of nitrogen and carbon dioxide.
- Approximately 40% propane in air.
What effect will inert gas have on the operation of an infrared type gas detector?
单选
- None. The instrument is not affected by the absence of oxygen.✓ 正确答案
- It will reduce the reading by contaminating the sensor.
- Small particles may obscure the mirrors.
- It will Increase the reading by increasing the temperature of the chamber.
开始前须知
开始前需要注册吗?
访客可试用 23 分钟。免费注册后可继续学习、保存进度并复习错题。
题目是什么语言?
题目和选项保留原语言。可以单独切换界面语言。
成绩可以作为正式文件吗?
不可以。这是自主练习,成绩无法替代授权机构的考试、证书或知识考核。