You are going to work on equipment that has been isolated, but which was previously pressurised or full of fluid. Which TWO of these precautions should be followed? Select the TWO best answers.
多选
Use any drain and vent valves fitted, checking that they are clear.✓ 正确答案
Loosen the bolts at off flanges but leaving the nuts on. Then just break the joint at the flange.✓ 正确答案
Give the isolating valves extra force with a wheel key.
Fully open a flange at the top of the equipment first.
How can safe isolation be maintained when more than one person is working on the same system, for instance in dry-dock? Select the ONE best answer.
单选
Each person should apply their own locks at the points of isolation.✓ 正确答案
There should be a verbal agreement to check with each other before restoring the equipment to service.
One person should agree to take charge of the situation.
They should leave the locking arrangements to the Master or Chief Engineer.
If the equipment you are working on can move downwards under gravity, what should you do to keep safe? Select the ONE best answer.
单选
Make sure that it is securely locked into position or properly supported.✓ 正确答案
Always work from above it.
Make sure that no-one can walk underneath it.
Only do the job when in port, so that the ship is not rolling.
If the person that applied the lock and tag out to a system is not available, what should be done when work is completed? Select the ONE best answer.
单选
Follow the on board procedure for such an event.✓ 正确答案
The Chief Engineer or Chief Mate will remove them.
Anyone who has been involved in the work can remove them.
Leave them in place till the original person is available.
You have been working on electrical, pneumatic or hydraulic equipment. What should be done about the controls for the equipment before re-energising it? Select the ONE correct answer.
单选
The controls should be put into a safe position, usually the ‘off’ position.✓ 正确答案
The controls should be checked to make sure they are in the same position they were when the work started.
Nothing needs to be checked, the equipment is not likely to start.
The controls should be placed to the ‘on’ position.