IG MARITIME 的国际模拟测试面向所有海员免费开放。注册一次即可保存进度,无限次备考!
请选择题集,开始学习或模拟考试。
题集简介
Seagull CBT 栏目提供自学题目。请选择一组题目,开始学习或模拟考试。
「Seagull CBT — CD0083. Automation」共有 1 个题集、13 道题。
学习
学习模式不限时。答题后可查看结果和正确选项,也可返回题目复习。
模拟考试
模拟考试最长 60 分钟,最多 50 道题。完成后可查看正确答案和成绩。
示例题目与答案
以下为题集中的示例。选择学习练习答题,或选择模拟考试检验知识。
What do we mean with a “180 grade fuel”?
单选
- Viscosity equal to or more than 180 cSt at 50 deg C.
- Viscosity equal to or less than 180 cSt at 70 deg C.
- Viscosity equal to or less than 180 cSt at 50 deg C.✓ 正确答案
- Viscosity equal to or more than180 cSt at 70 deg C.
What gives the best separating effect?
单选
- Low throughput (m3/hr) low viscosity.✓ 正确答案
- High throughput (m3/hr) low viscosity.
- Low throughput (m3/hr) high viscosity.
- High throughput (m3/hr) high viscosity.
Which statement is true?
单选
- The proportional feedback control can reduce error response to disturbances but that it still allows a non-zero steady-state error.✓ 正确答案
- The proportional feedback control can reduce error response to disturbances, and keep it to a steady correct value.
- The proportional feedback control cannot reduce any errors.
- The proportional feedback can raise error response.
What makes a Proportional-Integral-Derivative (PID) control different from a PI control.
单选
- The proportional band is narrower.
- The control switches before the signal overshoots the set point value.
- A "derivative" action increases the reaction time of the control system.✓ 正确答案
- There is no difference between a PID and a PI.
What are the highest viscosity modern diesel engines are capable of burning?
单选
- Approximately 1200 cSt, at 50° C.
- Approximately 700 cSt, at 50° C.✓ 正确答案
- Approximately 500 cSt, at 50° C.
- Approximately 1000 cSt, at 50° C.
开始前须知
开始前需要注册吗?
访客可试用 23 分钟。免费注册后可继续学习、保存进度并复习错题。
题目是什么语言?
题目和选项保留原语言。可以单独切换界面语言。
成绩可以作为正式文件吗?
不可以。这是自主练习,成绩无法替代授权机构的考试、证书或知识考核。