Which control mode is recommended during manoeuvring?
单选
Optimal, because this mode allows an increased load of the generators during manoeuvring
Equal, because of the wider control range which allows the low priority generator(s) to be connected at low loads✓ 正确答案
Cyclic, because the risk of fouling of intake channels are eliminated, and because of this the risks of reduced capacity of the generators are minimised
What will happen if Load dependent start/stop of generator sets is in auto mode?
单选
It will start/stop the generator sets in response to varying load✓ 正确答案
It will start/stop the generator sets in response to fuel consumption
It will start but never stop the generator sets in response to varying load
It will stop but never start the generator sets in response to varying load
The kW and kVAr instruments on the main switchboard reads respectively 630 kW and 400 kVAr. What is the actual power factor?
单选
0.8
0.85✓ 正确答案
0.9
How could you monitor the correct instant for synchronising without the aid of a synchroscope or synchronising lamps?
单选
By connecting a pair of voltmeter probes across one phase of the incoming generator circuit breaker, and then adjusting the generator speed until the voltmeter slowly fluctuates from zero to maximum. Connect the breaker when the voltmeter passes through zero✓ 正确答案
It is not possible to synchronise generators without the synchronising aids
By off-loading the running generator to a minimum to avoid large "kicks" at connection. Adjust the incoming generator to a frequency slightly less than the running generator. The running generator will then "pull" the incoming generator into synchronism
Which statement is true?
单选
The Priority 1 generator will be first IN / first OUT
The Priority 1 generator will be first IN / last OUT✓ 正确答案
At Cyclic control mode the generators change Priority order