All international training tests on IG MARITIME are free for every seafarer. Register once to save your progress and prepare for your next voyage without limits!

EN-IEB.AEN / OE1 / 5

Search this section

Choose a question set and start learning or take an exam.

About this collection

The ANR bank contains many sets with original names and codes, including navigation, safety and equipment topics. Select a module by name or use question search.

“ANR — IEB.AEN-Manag — EN-IEB.AEN / OE1 / 5” contains 72 questions across 1 collection.

Learning

Learning mode has no timer. After answering, you see feedback and the correct options. You can return to a question and repeat a topic.

Exam

A practice exam lasts up to 60 minutes and includes up to 50 questions from the selected collection. Correct answers and results appear after completion.

Sample questions and answers

These examples come from the published collection. Choose Learning to study questions in sequence, or Exam to check your knowledge.

Which of the referenced waveshapes would appear at point "X" of the circuit shown in the illustration?Question illustration

One correct answer

  • A✓ Correct answer
  • B
  • C
  • D
If a magnetic controller contactor fails to pick up when the coil voltage is applied to the contactor coil, the cause may be

One correct answer

  • overload
  • misalignment of the affected contactor contacts
  • low spring pressure
  • an open contactor coil✓ Correct answer
Which of the following is not a common application for a relay?

One correct answer

  • change alternating current to direct current✓ Correct answer
  • control a 120-V lighting circuit with a 24-V control circuit
  • control several switching operations by a single separate current
  • switch a high-current motor circuit ON and OFF with a low current control circuit
Which of the following is designed to provide machine operation protection by requiring the motor to be restarted after a power failure?

One correct answer

  • phase-reversal protection
  • ground-fault protection
  • low-voltage protection✓ Correct answer
  • low-voltage release
Which of the following statements represents the main difference between a relay and a contactor?

One correct answer

  • Contactors control current and relays control voltage.
  • A relay is series connected and a contactor is parallel connected.
  • Contactors can handle heavier loads than relays.✓ Correct answer
  • Contactors are made from silver and relays are made from copper.

Before you start

Do I need to register to start?

Guest access lasts 23 minutes. Free registration lets you continue without limits, save progress and review mistakes in your account.

What language are the questions in?

Questions and answer options retain the language of the original bank. You can change the interface language separately.

Can I use my result as an official document?

No. This is independent practice. A result does not replace an examination, certificate or knowledge check by an authorised organisation.